Electrolysis Blocker — Galvanic Isolator |
|
The MPS Electrolysis Blocker™ is an approved galvanic isolator.
It’s unique performance and features tested to the highest international marine standards.
A galvanic isolator is designed to block corrosion causing current that travels between vessels at a marina using a common shore power connection. The Electrolysis Blocker has failsafe construction that offers no ongoing maintenance or monitoring. The unit is compact and easy to install.
How It Works
Vessels in a marina are interconnected via the common shore earth which carries low voltage DC current between them and the marina.
This DC current is passed through the metal through hull fittings in to the water where it is free to contribute to galvanic corrosion. The result is more rapid consumption of anodes and then damage to unprotected submerged metal parts.
An Electrolysis Blocker™:
Blocks the damaging DC current
Maintains effective AC earth capability
Standards
AS/NZS3004.2.2008 & 3820:2009
ABYC A-28
Marine ISO 8846
Installation Instructions
The MPS Electrolysis Blocker must be installed by a licenced Electrician.
* The Electrolysis Blocker must be used in conjunction with a circuit breaker rated up to 16A max (minimum 5KA fault rated) and a 30mA residual current device.
The diagram below shows the general arrangements for electrical supply to a vessel with blocker installed. Further information can be obtained in Appendix B of AS/NZS3004.2
The Electrolysis Blocker shall be connected into the supply protective earthing conductor before it connects to the boats earth system. It should be installed where there is protection from accidental access, good ventilation, as close as practical to the shore power inlet / distribution panel and behind the appliance inlet. Use the mounting slots on the Blocker to secure it. The Electrolysis Blocker is installed in series in to the earthing conductor, the Blocker is clearly labelled “Ship Earth” and “Shore Earth”. The terminals of the Blocker should be treated as live parts.
The information stickers provided must be affixed in plain view on the front of the distribution panel.
Maintenance Instructions
The MPS Electrolysis Blocker does not require service or maintenance as it contains no moving or serviceable parts.
Boat owners are required to obtain an Electrical Warrant Of Fitness (EWOF) for all vessels with hard wired 240VAC electrical systems.
MPS recommend inspection periodically by a licenced electrician to ensure earth terminal connections remain secure and the unit stays properly mounted.
Electrolysis Blockers can be tested for performance and/or fault conditions by a qualified electrician using a multimeter.
The MPS Electrolysis Blocker is designed and sold for the purpose of galvanic corrosion protection and must not be used for any other use.
It’s unique performance and features tested to the highest international marine standards.
A galvanic isolator is designed to block corrosion causing current that travels between vessels at a marina using a common shore power connection. The Electrolysis Blocker has failsafe construction that offers no ongoing maintenance or monitoring. The unit is compact and easy to install.
- ISO, AS/NZS & ABYC standards certified approved
- 67A continuous current rating
- 5000A fail safe rating
- Compact for easy installation and inspection
- Waterproof-solid state components – no service required
- Proven high performance heat sink and ignition proof design
How It Works
Vessels in a marina are interconnected via the common shore earth which carries low voltage DC current between them and the marina.
This DC current is passed through the metal through hull fittings in to the water where it is free to contribute to galvanic corrosion. The result is more rapid consumption of anodes and then damage to unprotected submerged metal parts.
An Electrolysis Blocker™:
Blocks the damaging DC current
Maintains effective AC earth capability
Standards
AS/NZS3004.2.2008 & 3820:2009
ABYC A-28
Marine ISO 8846
Installation Instructions
The MPS Electrolysis Blocker must be installed by a licenced Electrician.
* The Electrolysis Blocker must be used in conjunction with a circuit breaker rated up to 16A max (minimum 5KA fault rated) and a 30mA residual current device.
The diagram below shows the general arrangements for electrical supply to a vessel with blocker installed. Further information can be obtained in Appendix B of AS/NZS3004.2
The Electrolysis Blocker shall be connected into the supply protective earthing conductor before it connects to the boats earth system. It should be installed where there is protection from accidental access, good ventilation, as close as practical to the shore power inlet / distribution panel and behind the appliance inlet. Use the mounting slots on the Blocker to secure it. The Electrolysis Blocker is installed in series in to the earthing conductor, the Blocker is clearly labelled “Ship Earth” and “Shore Earth”. The terminals of the Blocker should be treated as live parts.
The information stickers provided must be affixed in plain view on the front of the distribution panel.
Maintenance Instructions
The MPS Electrolysis Blocker does not require service or maintenance as it contains no moving or serviceable parts.
Boat owners are required to obtain an Electrical Warrant Of Fitness (EWOF) for all vessels with hard wired 240VAC electrical systems.
MPS recommend inspection periodically by a licenced electrician to ensure earth terminal connections remain secure and the unit stays properly mounted.
Electrolysis Blockers can be tested for performance and/or fault conditions by a qualified electrician using a multimeter.
The MPS Electrolysis Blocker is designed and sold for the purpose of galvanic corrosion protection and must not be used for any other use.